Skip to main content

Table 12 Agreement between the IFR results and the FFR results in the studied patients

From: Myocardial perfusion imaging by single-photon emission tomography (MPI SPECT) versus Instantaneous wave-free ratio (IFR) for assessment of functional significance of intermediate coronary artery lesions

IFR result

FFR result

Total

+ve

−ve

+ve

20

0

20

90.9%

0%

40.0%

−ve

2

28

30

9.1%

100%

60.0%

Total

22

28

50

100.0%

100.0%

100.0%

P value

< 0.001

Kappa Agreement

0.918

  1. Data were presented as number and percent
  2. N.B. the positive likelihood ratio was not calculated as the specificity was 100% and the PLR is calculated from the following equation: sensitivity/1−specificity = 90.9/1 − 1 = cannot be calculated