Skip to main content

Table 2 Procedural details

From: The impact of the use of bioresorbable vascular scaffolds and drug-coated balloons in coronary bifurcation lesions

Procedural details

BVS & DCB group (n = 40)

Access site

 Radial

32 (80%)

 Femoral

8 (20%)

 LM diseased

1 (2.5%)

 LAD diseased

23 (57.5%)

 LCX diseased

11 (27.5%)

 RCA diseased

8 (20%)

 Syntax score

15.04 ± 7.18

Medina class

 1,1,1

27(67.5%)

 1,1,0

0(0%)

 1,0,1

0%

 0,1,1

9 (22.5%)

 0,1,0

1 (2.5%)

 1,0,0

1 (2.5%)

 0,1,1

2 (5%)

 OCT

3 (7.5%)

 IVUS

10 (25%)

ACC/AHA

 A

0%

 B1

2 (5%)

 B2

34 (85%)

 C

4 (10%)

 Denovo lesions

100%

 ISR

0%

 Thrombus

5 (2.5%)

 CTO

6 (15%)

 RVD (proximal MV) (mm)

3.13 ± 0.4

 Lesion length (MV) (mm)

21.42 ± 16.25

 RVD SB (mm)

2.31 ± 0.34

 MLD MV (mm)

0.51 ± 0.37

 MLD SB (mm)

0.77 ± 0.62

 Lesion length (SB) (mm)

11.49 ± 6.35

 % stenosis MV

83.2 ± 13.4%

 % stenosis SB

66.79 ± 24%

 Predilatation MV

40 (100%)

 Predilatation MV balloon diameter

2.81 ± 0.45 m

 Predilatation pressure (atm)

13 ± 0.36

 Scoring balloon MV

1 (2.5%)

 Rotablator MV

0%

 Type of BVS

Absorb (100%)

 Length BVS (mm)

22.02 ± 6.07

 Second BVS used

7 (17.5%)

 Inflation pressure BVS (atm)

10.92 ± 1.4 atm

 Post dilatation of BVS

40 (100%)

 Post dilatation balloon diameter (mm)

3.31 ± 0.39

 Inflation pressure of postdilatation balloon (atm)

20.3 ± 4.4

Predilatation SB

32 (80%)

KB before stent implantation

5 (12.5%)

Kissing balloon inflation

23(57.5%)

Predilatation of SB balloon diameter

2.25 ± 0.33

Predilatation SB balloon inflation pressure

11 ± 3 atm

Type of DCB used

 Pantera Lux

6 (15%)

 Elutax SV

11 (27.5%)

 Restore

6 (15%)

 Sequent please

4 (10%)

 In.Pact Falcon

10 (25%)

 Danubu

1 (2.5%)

 Agent

1(2.5%)

 Magic

1 (2.5%)

 Diameter of DCB

2.43 ± 0.37 mm

 DCB length

20.36 ± 6.42 mm

 DCB inflation pressure

9.4 ± 1.9 atm

 DCB inflation duration

52 ± 10 sec

 FKB with normal balloons

6 (15%)

 FKB with DCB

17 (42.5%)

 Dissection left after DCB

6 (15%)

Type of dissections

 A

5 (12.5%)

 C

1 (2.5%)

Stenting of SB

0%

Final % diameter stenosis MB

5.3 ± 8%

Final % diameter stenosis SB

13.0 ± 16.4%

Final MLD MB (mm)

3.0 ± 0.43 mm

Final MLD SB (mm)

1.9 ± 0.5 mm

Total amount of contrast (ml)

212 ± 117

Procedural time (min)

71.8 ± 38 min

Total fluoroscopy time (min)

12 ± 3.9 min

BVS/DES-related complications

0%

BVS underexpansion

0%

Longitudinal deformation

0%

BVS recoil

0%

Final TIMI less than 3

0%

Intraprocedural occlusiom

0%

Intraprocedural death

0%

Peri-procedural MI

0%

Medications at discharge

 Aspirin

40(100%)

 Clopidogrel

11(27.5%)

 Prasugrel

4 (10%)

 Ticagrelor

25(62.5%)