Skip to main content

Table 2 Comparison between 2D-Wilkins score and 3D=Anwar score in cases with post-procedural optimal results, suboptimal MV area, and significant MR

From: Additive value of 3D-echo in prediction of immediate outcome after percutaneous balloon mitral valvuloplasty

  2D 3D P
Optimal post-procedural results (n = 36) Mobility 2.02 ± 0.51 2.29 ± 1.11 0.9
Thickness 1.88 ± 0.48 2.09 ± 0.74 0.5
Subvalvular apparatus 1.82 ± 0.62 2.11 ± 1.12 0.7
Calcification 0.79 ± 0.52 1.09 ± 1.37 0.1
Total score 6.51 ± 0.87 7.58 ± 2.18 0.6
Suboptimal post-procedural MVA (n = 6) Mobility 1.83 ± 0.41 4.16 ± 0.91 0.02
Thickness 2.16 ± 0.41 4.66 ± 1.03 0.03
Subvalvular apparatus 2.17 ± 0.41 7.01 ± 0.89 0.01
Calcification 0.83 ± 0.75 3.33 ± 1.03 0.007
Total score 6.99 ± 1.01 19.16 ± 3.86 0.008
Significant post-procedural MR (n = 8) Mobility 1.75 ± 0.71 3.37 ± 0.91 0.014
Thickness 1.88 ± 0.64 3.50 ± 0.53 0.001
Subvalvular apparatus 1.75 ± 0.46 4.12 ± 0.64 0.01
Calcification 1.25 ± 0.71 5.01 ± 0.75 0.01
Total score 7.79 ± 1.12 16.0 ± 2.83 0.03
  1. 2D 2-dimensional, 3D 3-dimensional, MV mitral valve, MR mitral regurgitation
  2. P value for comparison between both scores was estimated by Z score