Skip to main content

Table 5 Comparison between the 2 groups regarding TIMI flow, MBG, ST-segment resolution

From: Outcome of manual thrombus aspiration for patients undergoing primary PCI for acute STEMI showing large thrombus burden

 

Thrombus aspiration

Test value

P value

Sig.

No

Yes

No. = 136

No. = 73

TIMI

 I

9 (6.6%)

1 (1.4%)

7.823

0.020

S

 II

18 (13.2%)

3 (4.1%)

 III

109 (80.1%)

69 (94.5%)

MBG

 0

10 (7.4%)

1 (1.4%)

14.121

0.003

HS

 I

6 (4.4%)

0 (0.0%)

 II

41 (30.1%)

12 (16.4%)

 III

79 (58.1%)

60 (82.2%)

ST-segment resolution

 < 70%

18 (13.2%)

2 (2.7%)

16.674

0.000

HS

 > 70%

118 (86.8%)

71 (97.2%)