Skip to main content

Table 7 Logistic regression analysis for predictors of conduction disturbance

From: Impact of prosthesis oversizing on clinical outcomes of transcatheter aortic valve implantation using a self-expandable Evolut R valve

 

Uni-variate

Multi-variate

P-value

Odds ratio (OR)

95% C.I. for OR

P-value

Odds ratio (OR)

95% C.I. for OR

Lower

Upper

Lower

Upper

Euro score II > 5.58

0.001

4.069

1.714

9.661

0.711

0.735

0.145

3.739

STS score > 3.23

0.001

4.023

1.730

9.353

0.086

3.556

0.835

15.144

IHD

0.010

2.961

1.293

6.777

0.042

3.176

1.045

9.650

CVS

0.016

5.450

1.365

21.767

0.642

1.601

0.221

11.601

Septal Ca

0.029

3.061

1.119

8.373

0.269

2.407

0.506

11.440

DI > 3.4(mm)

0.000

9.294

3.485

24.783

0.389

2.454

0.319

18.903

DI i > 2.02 (mm/m2)

0.000

8.759

3.500

21.924

0.558

1.656

0.306

8.960

DIMS > 52.63%

0.000

9.652

3.888

23.957

0.181

2.947

0.604

14.374

RHD

0.029

5.641

1.189

26.758

0.004

32.239

3.044

341.432

DIDO ≤ 21%

0.024

10.482

1.367

80.349

0.176

5.228

0.476

57.425

  1. CVS Cerebrovascular stroke, DIDO Depth of implantation derived oversizing index, DI Depth of implantation, DI Depth of implantation indexed, DIMS Depth of implantation to membranous septum ratio, IHD Ischemic heart disease, RHD: Rheumatic heart disease, Society of thoracic surgery predicted risk of mortality