- Case Report
- Open access
- Published:
A new borne with very complex aortic anatomy: diagnosis and treatment challenge—case report
The Egyptian Heart Journal volume 72, Article number: 52 (2020)
Abstract
Background
Interrupted aortic arch (IAA) is a congenital malformation of the aortic arch which involves 3 out of 1 million live births. This congenital anomaly rarely occurs as an isolated lesion and is often associated with other intracardiac malformations, most commonly ventricular septal defect and patent ductus arteriosus (PDA). The diagnosis and surgical treatment of aortic interruption is usually challenging and may require multiple operations throughout the patient’s life.
Case presentation
This case represents a neonate with interrupted aortic arch (type B) and a very long segment of descending aorta hypoplasia and complex anatomy. The patient escaped early diagnosis at birth and presented few days later by a picture that mimicked severe sepsis and shock.
His aortic anatomy was very complex and he was treated with long extra-anatomical aortic interposition graft.
Conclusion
Aortic interruption is a rare congenital anomaly and is considered an extreme form of aortic coarctation.
It sometimes escapes early diagnosis due to the presence of patent ductus arteriosus and present later with shock and lactic acidosis. Sometimes the aortic anatomy is very complex and requires unusual surgical techniques for its repair.
Background
Interrupted aortic arch (IAA) is a rare congenital anomaly, and it is considered an extreme form of aortic coarctation. Celoria and Patton classified IAA into three major types [1, 5].
If not taken in account with high degree of suspicion, the patient may not be diagnosed at birth with few patients may even escape diagnosis till adulthood [6]. Although there are standard surgical techniques for the repair of IAA, sometimes the aortic anatomy is very complex requiring multiple operations and unusual treatment strategies [2, 3].
This case represents a neonate with interrupted aortic arch (type B), very long segment of descending aorta hypoplasia, and complex anatomy. He escaped diagnosis at birth and presented few days later by a picture that mimics severe sepsis and shock. He was treated with long extra-anatomical aortic interposition graft.
Case presentation
A full-term, newly born first baby for a non-consanguineous parent, presented 6 days after delivery with severe tachypnea, irritability, poor suckling, poor feeding, and lethargy.
The antenatal period was uneventful with no maternal illness or exposures, and the delivery was vaginal and was uneventful too.
On examination, the patient showed no dysmorphic feature, and he was in poor general condition, feeble crying, with marked tachypnea and tachycardia.
His arterial blood pressure was 64/30 mmHg, mean pressure 41 mmHg as measured from his left arm, heart rate of 163 bpm. The arterial blood pressure in his right arm was undetectable.
His skin was mottled with grayish appearance, and there was no peripheral pulsation in the lower half of his body. He had delayed capillary refilling (more than 6 s). Cardiac examination revealed a grade 2 systolic murmur on the base of the heart, with accentuated second heart sound.
His blood gases revealed lactic acidosis, hyperkalemia with high anion gap, and normal blood glucose level.
Laboratory investigations including blood cultures were withdrawn immediately, the patient was admitted to the neonatal intensive care unit (ICU), a central line was inserted, and the patient was intubated. Supportive treatment was started.
Differential diagnosis
Neonatal sepsis was the first differential diagnosis with septic shock, and other differential diagnoses are severe aortic coarcatation with duct-dependent systemic circulation and aortic interruption.
Echocardiography data
Situs solitus, levocardia, with normal connections, normal biventricular sizes and systolic functions, normal left-sided cardiac valves appearances with mild mitral regurgitation, with tricuspid aortic valve showing trivial aortic regurgitation. There was moderate degree of tricuspid regurgitation, and the estimated pulmonary artery pressure was found to be 65 mmHg after calculation of the right atrial pressure from the inferior venae cava size and variation with respiration.
There was a small mid-muscular ventricular septal defect (VSD) measuring 4 mm shunting bidirectionally with stretched foramen ovale.
There was a failure of clear visualization of the aortic arch and descending aorta from the supra-sternal window. The abdominal aortic flow from the subcostal views was non-pulsatile flow (monophasic flow) with minimal flow across a small closing patent ductus arteriosus (PDA).
Multidetector computed tomography (MDCT)
Right-sided aortic arch with mirror image arrangement of the arch vessels, aortic arch interruption after the right common carotid (type B aortic interruption), the proximal segment of the descending aorta after the interruption is markedly hypoplastic, under-filled, and receives its blood supply via multiple tiny collaterals with small closing PDA supplying the aorta distal to the interrupted segment.
The right subclavian artery arises from the descending aorta distal to the interrupted segment.
The length of the interrupted segment was about 10 mm. The proximal 20 mm of the descending thoracic aorta distal to the interruption was hypoplastic, under-filled, and measuring about 2 mm in diameter; the aorta at the diaphragm measured 5.8 mm.
The lower half of the body receives blood supply via anterior and posterior collateral circulations between the arch vessel branches (except the right subclavian artery) and the descending aorta and its branches and via a small PDA (Figs. 1 and 2)
Chromosomal testes
The presence of chromosome 22q11 deletion was excluded. Intravenous prostaglandin was started immediately with supportive treatment. The patient was referred for the cardiothoracic surgery.
The surgery was done after the patient’s stabilization late in the neonatal period in another cardiac center through a median sternotomy and selective cerebral perfusion by an extra-anatomical aortic interposition graft due to the relatively long segment of interruption, the small diameter of the descending thoracic aorta distal to the interrupted segment, and complex anatomy that precluded extended end to end anastomosis and primary repair.
Follow-up
One year after surgical repair MDCT showed a patent conduit (extra-anatomical aortic inter-position graft) from the ascending aorta that runs on the right lateral aspect of the heart, then its turns posteriorly to join the descending thoracic aorta just above the level of the diaphragm; there was no significant stenosis within. It measures about 10 × 10 mm in diameter, 70–75 mm in length (Figs. 3 and 4).
Discussion
Aortic interruption is a relatively uncommon congenital heart disease accounting for 1.5% of all congenital heart disease [1], with type B being the most common form accounting for (52–90%) [2, 3].
It is estimated that about 68% of the patient has associated chromosomal deletion and about 50% of patients have DiGeorge syndrome (abnormal facies, congenital heart defects, hypoparathyroidism, cognitive, behavioral and psychiatric problems, increased susceptibility to infections due to thymic aplasia, or hypoplasia) [4].
Our case did not have fetal echocardiography and was not diagnosed at birth mostly due to large PDA supplying the descending aorta; it was presented few days later by picture of shock, lactic acidosis, and hypoperfusion that poses some challenges in diagnosis.
There are different surgical techniques that are used for treatment of interrupted aortic arch, and some patients require multi-staged operations through their lifetime [1,2,3].
In our case, the surgeon could not do primary repair apparently due to the complex anatomy, so an extra-anatomical interposition graft was placed.
Conclusion
Aortic interruption may escape diagnosis at birth and present later in a picture that may be confusing with septic shock and lactic acidosis, high index of suspicion is mandatory for diagnosis. Rarely, aortic anatomy is very complex and needs unusual surgical techniques for repair.
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- IAA:
-
Interrupted aortic arch
- ICU:
-
Intensive care unit
- VSD:
-
Ventricular septal defect
- PDA:
-
Patent ductus arteriosus
- MDCT:
-
Multi-detector computed tomography
- 3D:
-
Three-dimensional
- MPR:
-
Multi-planar reconstruction
- MIP:
-
Maximal intensity projection
References
Luciani G.B., Ackerman R.J., Chang A.C., Wells W.J., Starnes V.A: One-stage repair of interrupted aortic arch, ventricular septal defect, and subaortic obstruction in the neonate: a novel approach, J Thorac Cardiovasc Surg , 1996, vol. 111 (pg. 48-358)
Tláskal T., Hucin B., Kucera V., Vojtovic P., Gebauer R., Chaloupecky V., Skovranek J.: Repair of persistent truncus arteriosus with interrupted aortic arch, Eur J Cardiothorac Surg , 2005, vol. 28 November (5)(pg. 736-741)
Pankaj Kumar Mishra, Management strategies for interrupted aortic arch with associated anomalies, Eu J Cardio-Thoracic Surgery, Volume 35, Issue 4, April 2009, Pages 569–576, https://doi.org/10.1016/j.ejcts.2008.12.044.
Van Mierop L.H., Kutsche L.M.. Cardiovascular anomalies in DiGeorge syndrome and importance of neural crest as a possible pathogenetic factor, Am J Cardiol , 1986, vol. 58 (pg. 133-137)
Celoria GC, Patton RB (1959) Congenital absence of the aortic arch. Am Heart J 58:407–413
Shirani S, Soleymanzadeh M (2013) Diagnosis of aortic interruption by CT angiography. Pol J Radiol 78(1):72–74. https://doi.org/10.12659/PJR.883771
Acknowledgements
Professor Alaa Roushdy, Professor of Cardiology, Ain Shams University, Congenital and Structural Heart Disease Unit, Ain Shams University.
Funding
This work did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Contributions
AM has contributed to all the stages of this work. The author read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
This publication was revised by out institutional review board and approved by our local ethical committee, with number 2754,2020. This was done in accordance with The Code of Ethics of the World Medical Association (Declaration of Helsinki).
Consent for publication
Written informed consent was obtained from the patient’s parents for publication of this case report and accompanying images.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Mansour, A. A new borne with very complex aortic anatomy: diagnosis and treatment challenge—case report. Egypt Heart J 72, 52 (2020). https://doi.org/10.1186/s43044-020-00086-w
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s43044-020-00086-w